Record Temperature Trends with ±0.1 % Accuracy
The 3441 and 3442 provide high-resolution measurements across a wide range of temperatures using K type thermocouples. With its drip-proof design, the 3442 delivers extended versatility, allowing use in moisture-prone environments when used with a special-purpose temperature probe.
• Model 3441 (°C only)
• Model 3441-02 (°C/°F selectable)
• Model 3442 (°C only, waterproof construction)
These products cannot perform measurement alone. Please purchase a temperature probe separately.
Model 3442: IP54 waterproof construction
• -100 to 199.9 ˚C: 0.1 ˚C resolution, 200 ˚C to 1300 ˚C: 1 ˚C resolution
• More than 200 hours (1 week) of continuous operation on a single battery
• Max./Min. value recording function and sensor disconnection check function
■ Basic specifications (Accuracy guaranteed for 6 months)
3441 | 3442 | ||
Sensor | K type thermocouple, (Chromel / Almel) | ||
Measurement range | -100 °C to 1300 °C The actual measurement range is restricted by the temperature probe (0.1 °C Resolution/ -100 °C to 199.9 °C, 1°C Resolution/ 200 °C to 1300 °C) |
||
Unit accuracy | ±0.1 % rdg. ±0.8 °C (-100 °C to 199.9 °C) ±0.2 % rdg. ± 1 °C (200 °C to 1300 °C) *Accuracy of temperature sensor is added |
||
Water-resistant Construction | N/A | IP 54 (EN 60529: 1991) | |
Sampling rate | 2 times/s | ||
Contact compensation | Auto compensation | ||
Functions | Max/Min data recording and display, display data hold, sensor broken down display, auto power save, low battery warning | ||
Power supply | R6P (AA) manganese battery ×4, or LR6 (AA) alkaline battery ×4, Continuous use : 200 hr or better (with manganese battery), Max. rated consumption : 35 mVA |
||
Dimensions and mass | 74 mm (2.91 in) W × 155 mm (6.10 in) H × 24 mm (0.94 in) D, 160 g (5.6 oz) | ||
Accessories | R6P (AA) manganese battery ×4, Strap band ×1, Instruction manual ×1 |
■ Probe specifications (9472, 9473, 9474, 9475: Waterproof construction)
*1 Sheath type: Responsiveness in ice water at 0 °C (32 °F) and in boiling water at 100 °C (212 °F)
Surface type: Responsiveness on a metal surface at 0 °C (32 °F) and at 100 °C (212 °F)
*2 At -40 °C (-40 °F ) and more , the greater of ±1.5 °C (±2.7 °F) and ±0.4 % of the measured value
*3 ±2.5 °C [ (T-Ts) ≤ 100°C ], -0.03 × T °C to +2.5 °C [100 °C < (T-Ts) ],
T : measured temperature (-40 °C to 500 °C), Ts : environmental temperature (0 °C to 40 °C)
Model | 9472 | 9473 | 9474 |
---|---|---|---|
Material type | K type thermocouple (Chromel / Almel) | ||
Contact type | Non-grounded | Non-grounded | Non-grounded |
Tolerance | *2 | ||
Response (90%)*1 | About 5 sec | About 10 sec | About 5 sec |
Size of Sheath (mm), (inch) | φ 2.3 × 150 (mm) φ 0.09 × 5.91 (in) |
φ 4.8 × 300 (mm) φ 0.19 × 11.81 (in) |
φ 2.3 × 100 (mm) φ 0.09 × 3.94 (in) |
Compensation lead | Conventional type (-20 to 90˚C, -4 to 194˚F), 1m (3.28 ft) | ||
Grip heat resistance | 80 ˚C (176 ˚F) | ||
Measurement temp. | -100 to 300 °C –148 to 572 °F |
0 to 800 °C 32 to 1472 °F |
-100 to 300 °C –148 to 572 °F |
■ Probe specifications (9180, 9183, 9181, 9182)
Model | 9180, 9183 | 9181 | 9182 |
---|---|---|---|
Material type | K type thermocouple (Chromel / Almel) | ||
Contact type | Non-grounded | Grounded | Non-grounded |
Tolerance | 9180 : *4 9183 : *2 |
±2.5 ˚C (±4.5 ˚F ) [(T-Ts) ≤ 100 ˚C (180 ˚F )] -0.035×T ˚C to +2.5 ˚C [100 ˚C (180 ˚F ) < (T-Ts)] T: measurement temp. (-50 °C to 400 °C) Ts: environment temp. (0 °C to 50 °C) |
*4 |
Response (90%)*1 | About 5 sec | About 3 sec | About 5 sec |
Size of sheath (mm), (inch) | φ 3.2 × 150 (mm) φ 0.13 × 5.91 (in) |
φ 13 (mm) φ 0.51 (in) |
φ 3.2 × 500 (mm) φ 0.13 × 19.69 (in) |
Compensation lead | Conventional type (-20 to 90˚C, -4 to 194˚F), 1m (3.28 ft) | Heat resisting type (0 to 150 °C, 32 to 302 °F) 2m (6.56 ft) | |
Grip heat resistance | 150 °C (302 °F), Grip size φ 13 × 100 mm (φ0.51 in × 3.94 in) | 90 °C (194 °F), clamp size φ 8 × 30 mm (φ 0.31 × 1.18 in) | |
Measurement temp. | -50 to 750 °C –58 to 1382 °F |
-50 to 400 °C –58 to 752 °F |