1mA to 200A AC Leakage Current Clamp Meter with 10 µA Resolution to Analyze Distorted Waveforms
• True RMS
• AC leak current and load current testing
• 10 mA leak current range with 10 µA resolution
• Load current up to 200 A
• Measure leakage current with absolute certainty using highly sensitive 10 μA resolution (at 10.00 mA range)
• Display 50/60 Hz leak current components using filtering function
• Monitor the leak current condition in combination with a Hioki Memory HiCorder (using monitor output)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
AC current | 10.00m/ 100.0m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt. |
---|---|
AC voltage | N/A |
Frequency | 30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt. |
Crest factor | 2.5 or less (1.5 at 200 A range) |
Filter function | Cut off frequency at filter ON: 180 Hz (-3dB) |
Output | REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms. MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB) |
Other functions | Max./ Min./ Average value record, Data hold, Auto power off |
Display | LCD, max. 2000 dgt., Display refresh rate: 4 times/s (FAST), 1 time/3 s (SLOW), 4 times/s (bar graph) |
Power supply | 6F22 (Stacked manganese battery) ×1, Continuous use: 40 hours, or AC adapter 9445-02/-03 |
Core jaw dia. | φ 40 mm (1.57 in) |
Dimensions and mass | 62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 400 g (14.1 oz) |
Accessories | Carrying Case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1 |