The KKInstruments high voltage testing equipment range has been specially designed for the safe and practical detection of voltages on electrical systems in the power generation and distribution, rail network, petrochemical and electrical service and maintenance industries.

The high voltage test range is designed for use on power system voltages of up to 33kV, and includes ergonomically designed portable neon and digital voltage indicators, capacitive voltage indicators, circuit phasing equipment, insulator leakage detectors and current clamps.

This highly specialist range of HV test equipment is in widespread use with test engineers and electrical power technicians worldwide, and has a longstanding reputation for reliability, accuracy and robust construction.

Importantly, with safety such a crucial factor, all Seaward high voltage testing equipment is fully compliant with international standards and is manufactured in compliance with IEC 61243.

Sub Categories

current-measurement
Specialist test equipment is available for the measurement of electrical current flow in overhead...
oil-testing
Highly refined insulating oils guarantee the successful operation of transformers, medical and...
  • Filter
Created on: 18 February 2014

 FEATURES ● Telescopic, compact, lightweight.● High voltage detection.● Self test button feature.● Easy to recognize indication.● High intensity red light emitting diode and intermittent audible sound    for easy recognition in full sunlight and noisy environments.● Waterproof.    SPECIFICATIONS           SEW0008 SEW0007 Withstand voltage (On insulating rod) 100kV / 300mm : 1 minutes Insulation resistance 2000MΩ min by 1kV / DC megger at the same testing location as withstand voltage Leakage current 100uA or less than 100uA at withstand voltage test Construction Water proof (detecting head impervious to water) Measuring voltage range 6kV~36.5kV 6kV~81.5kV Operation start voltage (To ground) 2.7kV 2.7kV Display Light : Flashing red light. Sound : Intermittent sound 50 dB apart 3 m. Frequency 50/60Hz Operating temperature 0°C ~ 40°C Battery 2 button-cells LR44(1.5V) ...

Created on: 18 February 2014

 FEATURES ● Telescopic, compact, lightweight.● High voltage detection.● Self test button feature.● Easy to recognize indication.● High intensity red light emitting diode and intermittent audible sound    for easy recognition in full sunlight and noisy environments.● Waterproof.    SPECIFICATIONS           SEW0008 SEW0007 Withstand voltage (On insulating rod) 100kV / 300mm : 1 minutes Insulation resistance 2000MΩ min by 1kV / DC megger at the same testing location as withstand voltage Leakage current 100uA or less than 100uA at withstand voltage test Construction Water proof (detecting head impervious to water) Measuring voltage range 6kV~36.5kV 6kV~81.5kV Operation start voltage (To ground) 2.7kV 2.7kV Display Light : Flashing red light. Sound : Intermittent sound 50 dB apart 3 m. Frequency 50/60Hz Operating temperature 0°C ~ 40°C Battery 2 button-cells LR44(1.5V) ...

Category: Proving units
Created on: 19 May 2013

Proving unit for use with high voltage indicators with a domed contact electrode High voltage output 1500V DC nominal Neon indicator to show output is active Very portable

Category: Proving units
Created on: 19 May 2013

● Designed to proof:     -Phasing sticks.     -High voltage detectors (contact type only, not to be used with non contact proximity detectors.)     -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.

Category: Proving units
Created on: 19 May 2013

● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.

Created on: 19 May 2013

100mm jaw opening Continuous readout or store options 2000A Range The lightweight Type L Plus large jaw current clamp meter is designed for the measurement of current in large diameter conductors and fuses.  Its 100mm jaw opening allows for use in most difficult situations, and is suitable for porcelain fuse carriers in distribution systems. High levels of insulation are incorporated for maximum safety and protection, together with the facility to provide complete linearity of measurement between 0 and 2000A featuring 3.5” LCD, and controlled using two main operating buttons. A TRACK facility provides a continuous readout and STORE facility monitors peak levels - ideally suited for monitoring maximum demand in electrical distribution networks.

Created on: 19 May 2013

Ammeter for overhead powerlines For use on overhead line systems up to 40 kV Simple to use membrane switches LCD display for readout and battery indicator The Halo has been designed for measuring current flow on overhead line systems up to 40 kV (line to earth). The sensing unit is encased in a moulded plastic housing and is fully screened against the effects of electrostatic fields.The RMS reading digital display is mounted in the fibre glass tubing body of the instrument and has a measurement range of 0A - 2000A. Using operator rods, the Halo is hooked over the conductor, and after 5 seconds the reading is stored and the instrument can be returned to ground level for the result to be recorded. The jaws are large enough to accommodate up to 50mm conductors. Measuring range 0 – 2000 Amps Accuracy 5% +/- 3 digits System voltage 40kV Display 3” digit digital display Operating temperature -10°C -+ 55°C Frequency 50Hz or 60Hz Battery 9v PP3 – 6R61 Weight 1.2kg Jaw size For conductors up to 50mm