BANTE

Sub Categories

Bante Instruments provides both the glass and plastic combination pH electrode for different...
Polarimeter is ideal for determining concentration levels of samples for applications in the...
Bante Instruments provides 9 models conductivity electrodes including the K series and CON series,...
Conductivity is used to measure the ability of an aqueous solution to carry an electrical current,...
Dissolved oxygen analysis is used to measures the amount of gaseous oxygen dissolved in an aqueous...
The following Ion Selective Electrodes can be used with any conventional laboratory or portable ion...
Bante Instruments provides 2 styles magnetic stirrers, JB-1A is a simple stirrer for education...
Bante9 series meters includes both portable and benchtop options for use either in the laboratory...
5 series ORP electrode used to measures the Oxidation-Reduction Potential of liquids, These sensors...
ORP measurements are used to monitor chemical reactions, quantify ion activity, or determine the...
Salinity meters are used for monitoring salt concentrations in natural water, drinking water, waste...
Total Dissolved Solids are the total weight of all solids that are dissolved in a given volume of...
  • Filter
Created on: 21 October 2014

Bante900P multi-parameter meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity TDS, Salinity, Resistivity, Dissolved Oxygen, etc. General Features: Automatic Temperature Compensation (ATC) ensures highly     accurate measurements over the entire range. Calibrationdue reminder helps you to calibrate meter regularly. Automatic endpoint function freezes stable measured values. Help message as a operational guide to helps you understand     how to use meter. Setup menu lets user customize the calibration points, stability     conditions, date and time to meet measurement requirements. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP. Stored data can be transferred into PC via USB communication     interface.

Created on: 21 October 2014

Bante980 is professional dissolved oxygen meter designed for laboratory applications. The meter is equipped with a polarographic sensor for measurement of dissolved oxygen concentration or percent saturation in water. Features: 1 or 2 points auto-calibration (100% in saturated air or air-saturated     water, 0% in zero oxygen solution). Automatically compensates salinity and barometric pressure after     manual input. Selectable readout in ppm, mg/L or % saturation. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Automatic Temperature Compensation (ATC) ensures high accuracy     of measurements. Manual temperature calibration provides accurate temperature value. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use meter.

Created on: 21 October 2014

Bante810 dissolved oxygen meter uses a polarographic sensor to measures dissolved oxygen concentration or percent saturation in water. The meter suitable for range of applications including the river monitoring, fisheries monitoring, etc.   Features: 1 or 2 points auto-calibration (100% in saturated air or air-saturated     water, 0% in zero oxygen solution). Manual salinity and barometric pressure compensation. Selectable readout in ppm, mg/L or % saturation. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Automatic Temperature Compensation (ATC) ensures high accuracy     of measurements. Manual temperature calibration provides accurate temperature value. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use meter.

Created on: 21 October 2014

Bante821 is professional dissolved oxygen meter designed for outdoor applications. The meter is equipped with a polarographic sensor for measurement of dissolved oxygen concentration or percent saturation in water.   Features: 1 or 2 points auto-calibration (100% in saturated air or air-saturated     water, 0% in zero oxygen solution). Automatically compensates salinity and barometric pressure after     manual input. Selectable readout in ppm, mg/L or % saturation. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Automatic Temperature Compensation (ATC) ensures high accuracy     of measurements. Manual temperature calibration provides accurate temperature value. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.

Created on: 21 October 2014

Bante820 is a basic portable dissolved oxygen meter that used for measuring the dissolved oxygen concentration or percent saturation in water. Features: 1 or 2 points auto-calibration (100% in saturated air or air-saturated     water, 0% in zero oxygen solution). Manual salinity and barometric pressure compensation. Selectable readout in ppm, mg/L or % saturation. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Automatic Temperature Compensation (ATC) ensures high accuracy     of measurements. Manual temperature calibration provides accurate temperature value. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.

Created on: 21 October 2014

DOscan10 pocket dissolved oxygen tester has a 6-pin connecter that used for connecting the DO probe. The tester used to measures dissolved oxygen concentration or percent saturation of water. Features: 1 or 2 points auto-calibration (100% in saturated air or air-saturated     water, 0% in zero oxygen solution). Manual salinity and barometric pressure compensation. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Hold function freezes the current displayed value for easy viewing     and recording. Setup menu lets user customize calibration points, temperature units,     automatic or manual hold function to meet personal preferences. Reset feature allows user to resume all of the default settings. Auto-power off feature helps you effectively conserve battery life. Replaceable electrode reduces maintenance and replacement cost. Waterproof feature to ensures complete protection in harsh     environments.

Created on: 21 October 2014

Bante950 is a professional multi-range conductivity meter which used for measuring the conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.

Created on: 21 October 2014

Bante540 portable conductivity meter used for measuring the electrical conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use...