FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Fuse protection function.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● hFE and db measurement.● With stand...makes reading and measuring easy.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC. dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 15mA, 150mA LV 3V Dimensions 102(L) × 148(W) × 46(D)mm Weight (battery included) Approx. 300g  Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V

Created on: 20 February 2014

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.● Packaging...packed completely with AL-21 test leads, hFE leads,   fuse, instruction manual.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g  Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V

Created on: 20 February 2014

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10dB~+22dB(for 10VAC)~+62dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V EN61010-2-030 EN61326-1

Created on: 20 February 2014

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and dB measurement.● LCD check function.● Battery test function.● Continuity test function.● With stand...makes reading and measuring easy.      SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 9kΩ/V AC dB -10dB~+22dB hFE 0-1000 LED check   ˇ Battery check GOOD or BAD ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V~0V Dimensions 100(L) × 150(W) × 41(D) mm Weight (battery included) Approx. 340g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V...

Created on: 20 February 2014

FEATURES ● High quality Taut Band movement.● Easy to read 3-color scale for mistake proof reading.● Mirror scale: makes reading pointer easy.● Safety features on all ranges.● Safety features: safety fused and safety “OFF” position.● dB measurement.● Built-in stand makes reading and measuring easy.     SPECIFICATIONS       DC Voltage     Ranges 0.25 / 1 / 2.5 / 10 / 50 / 250 / 1000V Accuracy ±2% of full scale Sensitivity 50kΩ / V AC Voltage     Ranges 2.5 / 10 / 50 / 250 / 1000V Accuracy ±3% of full scale Sensitivity 10kΩ / V Decibelmeter -20 to 62dB 0dB=1mW / 600Ω Direct Scale:-20 to +10dB DC Current     Ranges 25uA/1mA/25mA/500mA, 10A(on separate input) Accuracy ±2% of full scale Sensitivity 250mV AC Current     Ranges 10A Accuracy ±3% of full scale Resistance     Ranges R × 1           0.2 to 20kΩ R ×...

Created on: 20 February 2014

FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value   easier.● Auto ranging designed.● Range change function.● Continuity check.● Diode measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS       DC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V AC 4.000V 1mV 40.00V 10mV 400.0V 100mV 750V 1V ․Input impedance : 10MΩ DC...

Created on: 20 February 2014

FEATURES ● 3000 counts with a maximum display of 2999.● Angled display design helps the user to identify the     reading of value easier.● Auto scanning function for AC/DC voltage, and current.● Auto ranging.● Range change function.● Continuity check.● Diode & Capacitance measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS       DC Voltage         Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 3.000V 1mV 30.00V 10mV 300.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(1%rdg+5dgt) 800V...

Created on: 20 February 2014

FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value   easier.● Auto ranging designed.● Bar graph LCD display.● Range change function.● Relative/Maximum/Minimum modes.● Peak hold mode.● VAHz mode measures frequency in voltage or current mode.● 40M Hz frequency counter.● Auto Power off.● Continuity check.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS DC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V...