YOKOGAWA PORTABLE DATA LOGGER - DATUM Y XL120

A world first in data loggers! We are the first to obtain IPv6 Ready Logo Phase-1(ID:01-000273).
Portable size (155×155×55mm) and lightweight (approx. 800g) lets you carry with one hand.
Use of a color TFT LCD with wide viewing angle.

 
  • Set Temperature and Voltage Independently for Each Channel
  • All Channels Adopt Universal Insulated Inputs
  • Easy-to-Read Screen Display; Wide View TFT LCD (Even Outdoors)
  • Data Can be Saved at Max Speed of 100 ms
  • Acquire Large Amounts of Data
  • Employs Compact Flash and SD Cards
  • USB Memory Enables Support for a Data Copy Function
  • Supports Remote Data Acquisition
  • Alarm and Math Functions
Features
  • World first in measuring instruments! Obtained IPv6 Ready Logo Phase-1 (ID:01-000273)
  • Portable size (155×155×55mm) and lightweight (approx. 800g) lets you carry with one hand.
  • Wide viewing angle TFT-LCD
  • Best noise resistance performance in the category of handheld instruments.
  • Improves resistance to impact by use of rubber boots (standard accessory).
  • Web server, FTP server/client and e-mail distribution function are equipped as standard
  • Auto set & Auto run function by inserting external memory.
  • Alarm, Statistical operation and external function
Operating Temperature Range Indoor, at an altitude of 2000 meters or less
Storage Temperature -20 to 60°C
Storage Humidity Range 90%RH or less (no condensation)
Size Approx. 155 (W) × 155 (H) x 55 (D) mm (Without projecting parts
Weight Approx. 800g (Without battery and rubber boots)
Safety Standards EN61010-1
Measurement Category I (Max. Input voltage: 30VDC)
Pollution degree 2
EMC (emission) EN61326 Class A, EN61000-3-2,EN61000-3-3, EN55011Class A Group1
EMC (immunity) EN61326 Annex A
Standard Accessories AC adaptor: 100-240V 50/60Hz
CD-ROM (Standard software, USB driver, instructionmanual,
Communication function manual, quick manual)
Quick manual: x1
Rubber boots: Impact-resistant (93036)
Screwdriver: For push-lock screw
Terminal block: 8 channels (95052) or 16 channels(95053,95055)
Applications
  • Testing and evaluating product temperatures using a thermostatic chamber
  • Regular maintenance of various equipment (electric furnaces, inverter control units, injection molding machines, etc.)
  • Detecting and analyzing the cause of temperature changes associated with the malfunctions of equipment
  • Diagnosing the deterioration of batteries (up to 48 V)
  • Acquiring remote data using an internal LAN

SOFTWARE1

Standard Software (D-TOOL) Download

Exemption from Responsibility

  1. Yokogawa Meters & Instruments assumes no liability to any party for any loss or damage, direct or indirect, caused by the use of the product, or any unpredictable defect of the product.
  2. Modification of the product is strictly prohibited.
  3. Reverse engineering such as the disassembly or decompilation of software is strictly prohibited.
  4. No portion of the product supplied by Yokogawa Meters & Instruments may be transferred, exchanged, leased or sublet for use by any third party without the prior permission of Yokogawa Meters & Instruments.

Main Function

  1. Waveform display of measured binary data.
  2. Conversion to CSV for binary data.
  3. Copy function (clipboard copy)
  4. File division for binary data
  5. Settings and creation of setting files.

Updating Histories

DateVersionContents

Sep. 2011

2.03 D-TOOL Ver2.03 supports Windows 7 and YKMUSB USB driver.
< CAUTION >
If old USB driver for Datum-Y "BULKUSB.SYS" already installed, you must overwrite-install USB driver "YKMUSB" before using D-TOOL version 2.03 or later.
Jul. 2009 2.02 D-TOOL Ver2.02 supports Windows Vista
May. 2007 2.00 D-TOOL Ver2.00 supports XL100 series Ver. 3.00

System Requirements

OS:

  • Windows XP Home Edition SP1 or later
  • Windows Vista 32bit(Home Basic, Home Premium, Business, Ultimate)
  • Windows 7 32bit/64bit(Home Premium, Professional, Ultimate)

PC requirements: PC-AT compatible machine (DOS/V)

Display: XGA(1024*768) or higher resolution.

*Windows is registered trademarks of Microsoft Corporation.

Download File

  1. Click links of "D-TOOL_E_V203.zip" to download the compressed file.
  2. Unzip it and install software according to install manual.

D-TOOL UPGRADE file (Ver.2.03) D-TOOL_E_V203.zip (4.95 MB)

Download USB driver from the following link

USB Driver

For users who use old USB driver for Datum-Y

Please overwrite-install the USB driver "YKMUSB" before connecting to Datum-Y through USB communication on the D-TOOL version 2.03 or later.

Screenshot of device manager with old USB driver for Datum-Y

Datum Y USB Driver XP E 02

How to overwritHow overwrite-install the USB driver "YKMUSB"

See the Driver Installation Manual in the download site of USB driver.

USB Driver (Remove the Datum-Y from PC before USB driver installation.)

Screenshot of device manager after YKMUSB USB driver installation

YKMUSB1034 XP E 02

If you need old USB driver for Datum-Y, download from the following link.

USB_DRIVER.zip (17.4 KB)

(But this USB driver is unsupported by D-TOOL Ver 2.03 or later.)

SOFTWARE2

Optional Software (XL900) Download

Features

  • Real-time measurement at the maximum speed of 1 second
  • Zooming to analyze acquired data in the waveform view
  • A variety of data saving functions available (selective and partial saving)

Specification

  • Applicable models: Datum-Y firmware version 3.01 or later
  • Real-time measurement data acquisition functions
    • Communication interface: Ethernet, USB, RS-232, RS-485
    • Maximum number of units that can be connected: 10 units
    • Measurement acquisition period: 1 second to 1 hour
  • Display functions
    • Display: Waveform, Digital, Bar graph, Meter display
    • Cursor value display: Display of each measurement values, difference, maximum value, minimum value and average value of cursors A and B.
    • Other display functions: Horizontal Scroll, Resizing the Horizontal axis, Jump function, and more.
  • Dedicated calculation functions (available for Real-time measurement)
  • File processing functions: Partial storage, Divided storage, File division, Combined storage, and more.
  • Report format storage: Save maximum, minimum and average of hourly reports, daily reports, weekly reports and monthly reports in CSV format. Measurement data can be added to CSV data to be stored.
  • Other functions: Main unit setting functions, Clipboard copy functions, Printing functions.

System Requirements

OS Windows XP SP1 or later (Home, Professional), Windows Vista 32bit (Home Basic, Home Premium, Business, Ultimate), Windows 7 32bit/64bit (Home Premium, Professional, Ultimate)
Display XGA (1024 × 768) or higher, 65536 color or higher
CPU Pentium III 1.6 GHz or higher, Pentium 4 1.6 GHz or faster is recommended
Recommended memory capacity 512 MB or greater, 1 GB or greater
Required space on the HDD 1GB or greater

*Windows is registered trademarks of Microsoft Corporation

Updating Histories

DateVersionContents
Sep, 2011 2.02 Support Windows 7 and YKMUSB USB driver.
< CAUTION >
If old USB driver for Datum-Y "BULKUSB.SYS" already installed, you must overwrite-install USB driver "YKMUSB" before using Datum-LOGGER version 2.02 or later.
Aug, 2009 2.01 Support Windows Vista
May, 2007 2.00

Support XL100 series Ver. 3.00

About Update

  • How to use updates
    The update is free of charge to users who bought this product.
    Please follow these steps to get passcode to unzip the update.
    (Downloaded update is locked with passcode to unzip.)

  1. Press "Passcode Request"
    This email address is being protected from spambots. You need JavaScript enabled to view it.
  2. Write the following information in the created new mail window.
    - Name
    - Company
    - Division
    - Tel
    - Serial Number of your Datum-LOGGER *
    * It was written on the CD-ROM case.
  3. Please send it.
    We reply you with passcode to unzip the update.
  4. Start to unzip the update.
    And input passcode we send you when the update requests you to input passcode.

Latest update(Ver.2.02) Datum-LOGGER_E_V202.zip (9.45 MB)

Download USB driver from the following link:

USB Driver

For users who use old USB driver for Datum-Y.

Please overwrite-install the USB driver "YKMUSB" before connecting to
Datum-Y through USB communication on the Datum-LOGGER version 2.02 or
later.

Screenshot of device manager with old USB driver for Datum-Y

Datum Y USB Driver XP E 02

How to overwrite-install the USB driver "YKMUSB"

See the Driver Installation Manual in the download site of USB driver.

USB Driver (Remove the Datum-Y from PC before USB driver installation.)

Screenshot of device manager after YKMUSB USB driver installation

YKMUSB1034 XP E 02

If you need old USB driver for Datum-Y, download from the following link.

USB_DRIVER.zip (17.4 KB)

(But this USB driver is unsupported by Datum-LOGGER Ver 2.02 or later.)

FIRMWARE

Version up for Datum-Y firmware

Exemption from Responsibility

  1. Yokogawa Meters & Instruments assumes no liability to any party for any loss or damage, direct or indirect, caused by the use of the product, or any unpredictable defect of the product.
  2. Modification of the product is strictly prohibited.
  3. Reverse engineering such as the disassembly or decompilation of software is strictly prohibited.
  4. No portion of the product supplied by Yokogawa Meters & Instruments may be transferred, exchanged, leased or sublet for use by any third party without the prior permission of Yokogawa Meters & Instruments.

PRECAUTIONS

This manual describes how to upgrade the firmware or OS of Datum-Y in order to upgrade functions and modify defects.

  1. When you upgrade the firmware or OS of Datum-Y, follow carefully to the instructions.
    Make backup copy of the data in the Datum-Y internal memory to external memory cards.
  2. In the consequence of upgrading, the data saved in the Datum-Y is not guaranteed at all.
  3. Use the AC power supply and make sure the power does not go OFF during the upgrade operation.

Firmware Updating Histories

DateVersionContents
Nov, 2010 3.05 The reliability of the file writing was improved to respond to the unexpected such as interruption of power supply etc. when writing data to the file.
Dec, 2008 3.04 Function for specific customer was added.
Nov, 2008 3.03 A certain problem is found in an OS in use, the firmware was upgraded.
May, 2007 3.02 Function were added and upgraded as follows.
*Simultaneous communication service for LAN+RS-232, LAN+RS-485
*File divide function is added.
*Revised DCV:±50V range(used to ±30V)
*Revised from arithmetic function to four arithmetic operation (used to difference arithmetic)
*Revised Scaling setting manner

OS Updating Histories

DateVersionContents
Nov. 2010 2.10 The latest update program was applied to operating system (OS) used to the product.
Mar. 2009 2.02 While the LCD back light is off, the equipment is corrected which is noted only occasionally turns out to be failure when the back light is turned on by pressing any key.
Nov. 2008 2.01 A certain problem is found in an OS in use, the OS was upgraded.

REQUIREMENTS

Datum-Y
Datum-Y AC adapter
Compact Flash Card (Formatted): Product of SanDisk is recommended.

Download UPGRADE files and UPGRADE manual

UPGRADE Manual for Datum-Y (218KB)
UPGRADE_Ver3.05.zip (11.1MB)

*VerX.XX means the firmware version of Datum-Y

ACCESSORIES

Stand Supports 93039

For tilted installation on the desktop, wall mounting, and DIN rail mounting.
Approx. Height: 200 mm
Approx. Width: 150 mm
Approx Weight: 500 g

Location

Ask about this product