2-channel Current Logger to Easily Record Load Current of 50/60Hz Lines and Leak Current
Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5051 logs current over 2 channels in as fast as 1 second intervals.
Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20.
Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC
• Easily mount the light-weight , pocket-sized loggers in tight spaces
• Easy-to-see dual display
• Transfer data to PC even during recording
• Replace batteries while recording (30 second limit)
• 3 times the memory capacity compared to predecessor (Record 60,000 data per channel)
• Record without missing fluctuations in STAT mode
• Measurement data is preserved even after the battery dies
• Worry-free backup preserves recorded data even if a new measurement is started by mistake
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement items | AC current 2 channels (used with the optional current sensor; load current 2 ch, leak current 2 ch, or load/leak each 1 ch) |
---|---|
Measurement range | AC 500.0 mA to 1000 A rms, 5 range (depends on current sensor in use) |
Basic accuracy | ±2.0% rdg. ±0.13% f.s. (main unit + current sensor accuracy, at 500.0 A range, 50/60 Hz) Note: Basic accuracy is typical value, only main unit accuracy: ±0.5 %rdg. ±5 dgt., must added clamp sensor accuracy, refer to the detailed catalog |
Storage capacity | Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch |
Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced |
Waterproof and dust-proof | N/A |
Interfaces | Infrared optical communications with LR5091, LR5092-20 |
Power supply | LR6 (AA) Alkaline battery ×2, Battery life: Approx. 1 year (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 1 month (Instantaneous recording, with 1-second interval at 20 °C) |
Dimensions and mass | 79 mm (3.11 in) W × 70 mm (2.76 in) H × 37 mm (1.46 in) D, 165 g (5.8 oz) |
Accessories | LR6 (AA) Alkaline battery (built-in internal) × 2, Instruction manual × 1, Operation guide × 1 |