BANTE

Sub Categories

Bante Instruments provides both the glass and plastic combination pH electrode for different...
Polarimeter is ideal for determining concentration levels of samples for applications in the...
Bante Instruments provides 9 models conductivity electrodes including the K series and CON series,...
Conductivity is used to measure the ability of an aqueous solution to carry an electrical current,...
Dissolved oxygen analysis is used to measures the amount of gaseous oxygen dissolved in an aqueous...
The following Ion Selective Electrodes can be used with any conventional laboratory or portable ion...
Bante Instruments provides 2 styles magnetic stirrers, JB-1A is a simple stirrer for education...
Bante9 series meters includes both portable and benchtop options for use either in the laboratory...
5 series ORP electrode used to measures the Oxidation-Reduction Potential of liquids, These sensors...
ORP measurements are used to monitor chemical reactions, quantify ion activity, or determine the...
Salinity meters are used for monitoring salt concentrations in natural water, drinking water, waste...
Total Dissolved Solids are the total weight of all solids that are dissolved in a given volume of...
  • Filter
Category: pH Meters
Created on: 21 October 2014

Bante221 is a high performance portable pH/ORP meter designed for outdoor applications. The meter contains a built-in setup menu that provides many advanced and useful options to improve accuracy of measurement and simplify operation.   Features: During the pH mode, Up to 5 points push-button calibration with auto-     buffer recognition. Selectable pH buffer standards and temperature units. Automatically calculates and shows electrode slope after calibration. Automatic Temperature Compensationensures highly accurate     measurement over the entire pH range. Calibration due reminder prompts you to calibrate the meter regularly. During the ORP mode, 1 point offset calibration allows user to adjust     displayed value to a known standard. Absolute or Relative millivolt (R.mV) measurement provides accurate     ORP readings. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.

Category: pH Meters
Created on: 21 October 2014

Bante320 is a multi-parameter ion meter used for measuring the ion concentration and pH value of liquids. The meter is equipped with a BNC connecter that can connects various combination Ion Selective Electrodes.   Features: During the pH mode, Up to 5 points push-button calibration with auto-     buffer recognition. Selectable pH buffer standards and temperature units. Automatically calculates and displays electrode slope after calibration. During ORP mode, Single point offset calibration allows user adjusts     displayed value to a known standard. Absolute or Relative millivolt (R.mV) measurement provides accurate     ORP readings. During the ion mode, 2 to 5 points push-button calibration from low to     high concentrations. Selectable multiple concentration units, including ppm, mg/L and mol/L. Direct readout ion concentration simplifies the elaborate measurement     process.

Category: pH Meters
Created on: 21 October 2014

PHS-W series is an easy-use basic pH meter designed for daily testing and controls are required. Automatic Calibration: The meters is capable of calibrating up to 2 points using USA or NIST pH standard buffer. Press the CAL key to enter calibration mode and immerse pH sensor into indicated calibration solutions, press ENTER key and meter is automatically calibrated.   Auto-Buffer Recognition: During the calibration, if the calibration solution does not match meter indicated value, an ERROR indicator will be displayed. After calibration, the percentage slope of the electrode is displayed before the meter return to pH measurement mode. Per the electrode slopes, you can decides whether to replace the sensor. Automatic or Manual Temperature Compensation: The meter provides manual or automatic temperature compensation mode for optimum accuracy under variable temperature conditions. The integrated plastic housing & keypad is sealed to protect against accidental spills, The holder arm is rapidly switched to both sides & swivels and articulates for convenient use and positioning.

Category: pH Meters
Created on: 21 October 2014

PHS-W series is an easy-use basic pH meter designed for daily testing and controls are required. Automatic Calibration: The meters is capable of calibrating up to 2 points using USA or NIST pH standard buffer. Press the CAL key to enter calibration mode and immerse pH sensor into indicated calibration solutions, press ENTER key and meter is automatically calibrated.   Auto-Buffer Recognition:   During the calibration, if the calibration solution does not match meter   indicated value, an ERROR indicator will be displayed.   After calibration, the percentage slope of the electrode is displayed   before the meter return to pH measurement mode. Per the electrode   slopes, you can decides whether to replace the sensor.   Automatic or Manual Temperature Compensation:   The meter provides manual or automatic temperature compensation   mode for optimum accuracy under variable temperature conditions.   The integrated plastic housing & keypad is sealed to protect against   accidental spills, The holder arm is rapidly switched to both sides &   swivels and articulates...

Category: pH Meters
Created on: 21 October 2014

PHS-W series is an easy-use basic pH meter designed for daily testing and controls are required. Automatic Calibration: The meters is capable of calibrating up to 2 points using USA or NIST pH standard buffer. Press the CAL key to enter calibration mode and immerse pH sensor into indicated calibration solutions, press ENTER key and meter is automatically calibrated.   Auto-Buffer Recognition: During the calibration, if the calibration solution does not match meter indicated value, an ERROR indicator will be displayed. After calibration, the percentage slope of the electrode is displayed before the meter return to pH measurement mode. Per the electrode slopes, you can decides whether to replace the sensor. Automatic or Manual Temperature Compensation: The meter provides manual or automatic temperature compensation mode for optimum accuracy under variable temperature conditions. The integrated plastic housing & keypad is sealed to protect against accidental spills, The holder arm is rapidly switched to both sides & swivels and articulates for convenient use and positioning.

Category: pH Meters
Created on: 21 October 2014

Bante210 standard pH meter is an easy-use benchtop meter designed for daily testing and controls. Features: Large backlit LCD display shows mode indicators and help messages. Up to 3 points push-button calibration with auto-buffer recognition. Selectable pH buffer standards and temperature units. Automatically calculates and shows electrode slope after calibration. Automatic Temperature Compensationensures highly accurate     measurement over the entire pH range. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide that can help users quickly use     the meter. Setup menu lets user customize buffer standard, calibration points,     temperature unit, automatic or manual hold function, auto-off feature     to meet personal preferences. Reset function can resumes all settings tofactory default values.

Category: pH Meters
Created on: 21 October 2014

Bante920 is a high precision pH meter which is equipped with large backlit LCD display. The meter can displays many useful prompt messages to helps you quickly and easily measuring the samples.   Features: During the pH mode, Up to 5 points push-button calibration with auto-     buffer recognition. Selectable pH buffer standards and temperature units. Automatically calculates and displays electrode slope after calibration. Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. During ORP mode, Single point offset calibration allows user adjusts     displayed value to a known standard. Absolute or Relative millivolt (R.mV) measurement provides accurate     ORP readings. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.   Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand...

Category: pH Meters
Created on: 21 October 2014

Bante930 is a high accuracy meter used for measuring the ion concentration, ORP and pH values of liquids. The meter widely used in environmental studies, chemical labs, swimming pools, spas to monitor the chemical reaction of water.   Features: During the pH mode, Up to 5 points push-button calibration with auto-     buffer recognition. Selectable pH buffer standards and temperature units. Automatically calculates and displays electrode slope after calibration. During ORP mode, Single point offset calibration allows user adjusts     displayed value to a known standard. Absolute or Relative millivolt (R.mV) measurement provides accurate     ORP readings. During the ion mode, 2 to 5 points push-button calibration from low to     high concentrations. Selectable multiple concentration units, including ppm, mg/L and mol/L. Direct readout ion concentration simplifies the elaborate measurement     process.   Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire...