GW INSTEK LCR-8000G Series

Category: LCR Meters

Features:

※ Wide Test Frequency 20Hz ~ 10/5/1MHz
※ 0.1% Basic Accuracy & 6 Digits Measurement Resolution
※ Large LCD Display with Intuitive Interface
※ Full Measuring Functions with DUT V/I Monitor
※ PASS/FAIL Function ( abs, % or delta) with Judgment Alarm
※ DC Resistance Measurement
※ Multiple Step Mode
※ Standard RS-232C/GPIB Interface
※ Optional DC Bias box

Description:

The LCR-8000G Series LCR meter, with test frequency up to 10MHz, provides accuracy, versatility and high resolution for a wide range of component measurements, even including DC resistance measurement and Voltage/Current monitoring. The Multi-Step function allows on-screen programming of customized measurement sequence with Pass/Fail indication. Each program includes 30 test steps and each test step can be set with selected parameters and test limits. Under Multi-Step operation, a tedious work routine can be done step by step automatically just at a press of a button. With Graph Mode, LCR-8110G, LCR-8105G and LCR-8101G display the component impedance response either over a wide range of test frequency sweep or over a wide range of test voltage sweep in a graph chart. This gives an analysis result of either impedance vs. frequency or impedance vs. applied voltage all at a glance. GPIB and RS-232C interfaces are available as standard for instrument control and test result display on the PC. The rich features of LCR-8000G Series easily make your measurement tasks done at a very competitive price.

The Smarter Way to Characterize Component


Front Panel
Rear Panel
 
 
Friendly Intuitive User Interface
The LCR-8000G Series is designed to perform precision impedance measurements over a wide frequency range of 20Hz~10MHz for LCR-8110G, 20Hz~5MHz for LCR-8105G and 20Hz~1MHz for LCR-8101G.The instrument is capable of measuring 11 different parameters with0.1% basic accuracy, which meets the precision measurement requirements of components and modules used in the RF circuits. The large LCD display with single-layer operation menu of LCR-8000GSeries provides users with ultimate convenience to plug and play without much learning time.
 
Pass/Fail Function with Judgment Alarm
In the Pass/Fail test, primary parameter measurement result is compared with user-defined limits and the pass or fail result is then displayed. Three methods, including absolute limit, percentage and delta limit, are available for Hi(high) and Lo(low) limit setting based on the nominal test value. The Pass/Fail test checks whether the parameter measurement result sits within the limits, then display "PASS" for within the limits, or "LO" for lower than the low limit, or "HI" for higher than the high limit. A scale and bar for displaying measurement result is shown at the center of the screen to give a graphical identification, which greatly reduces operator's load in a long time inspection work. This scale and bar also facilitate the adjustment of the variable components. Either Pass or Fail result can be set with a buzzer alarm, which makes component or material sorting easy with sound identification.
 
Multi Step Mode
The Multi-Step mode is capable of running a series of measurements of a component at a number of user-defined steps in sequence automatically. Total 64 programs can be saved into the non-volatile memory, and each program contains up to 30 test steps. The parameter and Hi/Lo limits can be set respectively for each test step. After a program being properly edited, the instrument can run through all the measurement steps either at a press of the button under the Manual Trigger selection, or automatically run the program by detecting the connection of a DUT under the Auto Trigger selection. When all the test steps are completed, the screen shows the measurement reading of the parameter being selected for each step with Pass, HI, or LO measurement result.
 
Graph Mode
The graph function shows the component characteristics in visual manner. Either voltage sweep or frequency sweep can be selected for horizontal scale. Just select the parameter, and set the start/stop voltage or the start/stop frequency of the sweep, LCR-8000G will run through the sequence of measurements and show the results on a graph. This graphical parameter measurement performs the characteristic verification of components and materials over the response to the changes in AC test frequency or AC test voltage without the need of complex programming of an external controller. When the graph gets out of the vertical range, the LCR-8000G Series can automatically adjust the scale to get full test information. On the graph the marker operation is available for detailed observation.

Specification:

TEST FREQUENCY
20Hz ~ 10 / 5 / 1 MHz, 5 Digits, ±0.005%
INPUT IMPEDANCE
100Ω
BASIC ACCURACY (*)
±0.1% (R, Z, X, G, Y, B, L, C)
TEST SPEED
AC ( 2kHz)
MAX: 75mS
FAST: 150mS
MEDIUM: 450mS
SLOW: 600mS
DC
MAX: 30mS
FAST: 60mS
MEDIUM: 120mS
SLOW: 900mS
TEST SIGNAL LEVELS
3MHz:10mV~2Vrms, 1mV/Step or 10mV/Step, 2%±5mV
3MHz:10mV~1Vrms, 1mV/Step or 10mV/Step, 2%±5mV
SHORT CIRCUIT CURRENT
Max. 20mA
MEASUREMENT RANGES
R, Z, X 0.1mΩ ~ 100MΩ
G, Y, B 10nS ~ 1000S
L 0.1nH ~ 100kH
C 0.01pF ~ 1F
D 0.00001 ~ 9.9999
Q 0.1 ~ 9999.9
θ -180° ~ +180°
Rdc 0.1mΩ ~ 100MΩ
MEASUREMENT PARAMETERS
Impedance (Z), Phase Angle (θ), Inductance (L), Capacitance (C), AC Resistance (Rac), Quality Factor (Q), Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Susceptance (B), DC Resistance (Rdc)
SERIES OR PARALLEL EQUIVALENT CIRCUIT
C + R, C + D, C + Q, L + R, L + Q, L + D
SERIES EQUIVALENT CIRCUIT ONLY
X + R, X + D, X + Q
PARALLEL EQUIVALENT CIRCUIT ONLY
C + G, B + G, B + D, B + Q, B + R, L + G
POLAR FORM
Z + Phase Angle, Y + Phase Angle
AVERAGE
1 ~ 256 TIMES
LCD DISPLAY
320 x 240 DOT-MATRIX
INTERFACE
RS-232, GPIB
POWER SOURCE
AC 115V(+10% / -25%), 230V(+15% / -14%) (Selectable), 50/60Hz
DIMENSIONS & WEIGHT
330(W) x 170(H) x 340(D)mm, Approx. 5kg

(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the device under test.

 

Accessories:

User manual x1, Power cord x1, LCR-12 x1
 
 
OPTIONAL ACCESSORIES
Opt.01 GTL-251 GPIB-USB-HS (High Speed)
Opt.02 DC Bias box (Freq. upto 2MHz / max. input voltage +/- 200V)
 
 
OPTIONAL ACCESSORIES
Accessory Model Brief Description
LCR-8110G
LCR-8105G
LCR-8101G
LCR-05 Test Fixture for axial & radial leaded components
V
LCR-06A Test Lead with Kelvin clip (4 wire type)
V
LCR-07 Test Lead with Alligator clip (2 wire type)
V
LCR-08 Test Fixture (Tweezers) for SMD/Chip components
V
LCR-09 Test Fixture for SMD/Chip components
V
V
V
LCR-12 Test Lead with Kelvin clip (4 wire type)
V
V
V
LCR-13 Test Fixture for SMD/Chip components
V
V
V
GTL-232 RS-232C Cable
V
V
V
GRA-404 Rack Adapter Panel (19", 4U)
V
V
V
GTC-001 Instrument Cart
V
V
V
GTC-002 Instrument Cart
V
V
V

Note " △ " means the accessories work with a frequency limitation (under 1MHz)
 

Ordering Information:

LCR-8110G 10 MHz Precision LCR Meter
LCR-8105G 5 MHz Precision LCR Meter
LCR-8101G 1 MHz Precision LCR Meter

Download:

Marcom Tool
 
 
Description
 
 
 
     4133 K     LCR-8000G Brochure (pdf)    en    V3   2010/08/11
     536 K     LCR-8000G datasheet (pdf)    en    V3   2010/08/11

 

Manual
 
 
Description
 
 
 
     2481 K     LCR-8000G User Manual (pdf)    en    VD   2011/04/13

 

Examples
 
 
Description
 
 
 
     92743 K     How to connect bias box to LCR meter    nil    0   2014/8/17
     72633 K     How to connect test lead and power supply to bais box    nil    0   2014/8/17
     325775 K     Zero the entire testing set (bias box, test lead and power supply) after connection    nil    0   2014/8/17
     325775 K     Zero the entire testing set (bias box, test lead and power supply) after connection    nil    0   2014/8/17

 

Software
 
 
Description
 
 
 
     10097 K     LCR-8000G PC Software (for RS232 connection only and Microsoft Excel is required)    en    V1.03   2012/11/27

 

 

 

 

Location

Ask about this product